Los contactores AX50...AX80 se utilizan principalmente para controlar motores trifásicos y circuitos de potencia de hasta 690 V CA. Estos contactores son de tipo bloque con: - 3 polos principales - circuito de control: AC operated - add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Especificaciones Tecnicas
CaracteristicasDato:
Number of Main Contacts NO 3
Number of Main Contacts NC 0
Number of Auxiliary Contacts NO 0
Number of Auxiliary Contacts NC 0
Rated Operational Voltage Auxiliary Circuit 690 V Main Circuit 690 V
Rated Frequency (f) Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1 Open Contactors ? = 40 °C 100 A
Rated Operational Current AC-1 (Ie) (220 / 240 V) 55 °C 85 A (690 V) 40 °C 100 A (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie) (415 V) 55 °C 50 A (440 V) 55 °C 45 A (500 V) 55 °C 45 A (690 V) 55 °C 35 A (380 / 400 V) 55 °C 50 A (220 / 230 / 240 V) 55 °C 53 A
Rated Operational Power AC-3 (Pe) (415 V) 25 kW (440 V) 25 kW (500 V) 30 kW (690 V) 30 kW (380 / 400 V) 22 kW (220 / 230 / 240 V) 15 kW
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Maximum Electrical Switching Frequency (AC-1) 600 cycles per hour (AC-3) 600 cycles per hour
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp) Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency 3600 cycles per hour
Rated Control Circuit Voltage (Uc) 50 Hz 220 ... 230 V 60 Hz 230 ... 240 V
Operate Time Between Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection acc. to IEC 60529 IEC 60947-1 EN 60529 Coil Terminals IP20 acc. to IEC 60529 IEC 60947-1 EN 60529 Main Terminals IP10 IP10
Terminal Type Screw Terminals